House came with a well drilled in 1994 and the pump looks original, what should I budget to fail first?
Water pressure is fine, no staining, and the previous owners left a folder with the original driller's log and nothing since. I have never lived on a well and I would rather set money aside now than find out on a holiday weekend. Two adults, no irrigation, and the wellhead is about forty metres from the house.
@wormbin_walt · 6mo ago · 3 replies
Order of likely failure from what I have seen: pressure switch first, which is a cheap part and easy to swap; then the pressure tank, where the bladder goes and the pump starts short-cycling; then the pump itself, which on a residential submersible is often somewhere in the eight to fifteen year range depending on how hard it works and what is in the water. The well itself, the hole, the casing: usually outlives all of that by decades. So the 1994 date is much less alarming than an original pump would be.
Reply
Report
@gio_castellan · 6mo ago
A well contractor can often tell from the model and the wiring. Worth paying for one service visit now purely to get that answer and a baseline.
Reply
Report
@caulkgun_carla · 6mo ago
So the number to worry about is the pump's age, not the well's. Nothing in the folder tells me when it was put in.
Reply
Report